Filter by Subcategory
Ohio (HVAC)
Heat Pump Install & Service: Florence, KY
with Eric Richardson

This class covers:
- Installation and service of heat pump systems.
- New communicating systems and how to setup the system for maximum efficiency.
- Proper check out and operation of the reversing valve and defrost boards.
- 454B updates and equipment covered
Class approved for 4 hours KY Masters/Journeyman, 4 hours OH, 4 hours Vanderburg Co, IN Masters, and NATE CEUs. Per state rules, repeat courses do not qualify for accumulative credits. Each class must be unique. i.e. Taking (2) Heat Pump Classes only qualifies for 4 CEUs total, whereas (1) Inverter Technology Class & (1) Heat Pump Class = 8 CEUs
Refreshments/dinner provided
LG Residential & Light Commercial Essentials Training: Florence, KY
with Marty Newberry

Residential & Light Commercial Essentials Training
Who Should Attend:
Employees and subcontractors of LG Representatives and Distribution Partners who will be servicing and repairing LG ductless air conditioning systems.
Course Overview – What You’ll Learn:
This course provides an in-depth look at the key components of LG ductless systems, including PCBs, EEVs, BLDC motors, compressors, and more. Students will gain a modular-level understanding of how each component contributes to the proper operation of the system. Instruction will also cover electrical connections—both indoor and outdoor—and how these elements interact. The course includes hands-on guidance for accessing major system components and performing essential service and maintenance tasks.
How You’ll Learn:
Training combines classroom-based instruction with practical, hands-on exercises using live LG equipment in the lab. Students will follow a step-by-step troubleshooting process and use LGMV Mobile, LG’s performance and diagnostic tool, to evaluate and resolve real-time equipment issues.
Prerequisites:
- Advanced technical knowledge of residential A/C, heat pump, and air distribution systems
- Basic working knowledge of Microsoft Office programs including Excel, PowerPoint, and Word
LGMV Note:
Students interested in using the LGMV PC version should contact their Representative or Distributor to obtain an LGMV kit.
What to Bring:
- A laptop or PC with a web browser (Internet Explorer 8.0 or higher)
- Students who wish to have LGMV installed on their computer should ensure compatibility in advance
Registration:
Participants must register at https://lghvac.com/training/ to receive LG Pro Dealer credit and a certificate of completion.
Extras:
Refreshments and lunch are provided
Class approved for 4 hours KY Masters/Journeyman, 4 hours OH, 4 hours Vanderburg Co, IN Masters, and NATE CEUs. Per state rules, repeat courses do not qualify for accumulative credits. Each class must be unique. i.e. Taking (2) Heat Pump Classes only qualifies for 4 CEUs total, whereas (1) Inverter Technology Class & (1) Heat Pump Class = 8 CEUs
Will run
Lochinvar Noble Combination high efficiency boiler and domestic hot water: hands on: Florence KY
with Factory Representative

This class is a hands on experience, teaching best practices for sizing, installation and service.
Course work will include interacting with:
- a Noble Combi boiler
- domestic hot water production
- two zones of heating
- pumps
- zone valves
- air control
- water quality control
- hydraulic separation
Class approved for 2 hours KY Masters/Journeyman only. Per state rules, repeat courses do not qualify for accumulative credits. Each class must be unique. i.e. Taking (2) Heat Pump Classes only qualifies for 4 CEUs total, whereas (1) Inverter Technology Class & (1) Heat Pump Class = 8 CEUs
Heat Pump Install & Service: Online (no CEs)
with John Ogle

This class covers:
• Installation and service of heat pump systems.
• New communicating systems and how to setup the system for maximum efficiency.
• Proper check out and operation of the reversing valve and defrost boards.
• 454b review and updates
Login information will be emailed
Heat Pump Install & Service: Online (with CEs)
with John Ogle

This class covers:
• Installation and service of heat pump systems.
• New communicating systems and how to setup the system for maximum efficiency.
• Proper check out and operation of the reversing valve and defrost boards.
• 454b review and updates
Login information will be emailed
Class approved for 4 hours KY Masters/Journeyman, 4 hours OH, 4 hours Vanderburg Co, IN Masters, and NATE CEUs. Per state rules, repeat courses do not qualify for accumulative credits. Each class must be unique. i.e. Taking (2) Heat Pump Classes only qualifies for 4 CEUs total, whereas (1) Inverter Technology Class & (1) Heat Pump Class = 8 CEUs
LG Residential & Light Commercial Installation Training: Florence, KY
with Marty Newberry

Who Should Attend:
Employees and subcontractors of LG Representatives and Distribution Partners who will be performing field installations of LG ductless systems.
Course Overview – What You’ll Learn:
This training covers the manufacturer’s guidelines for installing piping and wiring systems associated with LG Duct-Free Split (DFS) indoor and outdoor air conditioning units.
How You’ll Learn:
The session begins with a brief introduction to LG inverter technology, followed by detailed lectures focused on system installation—with a strong emphasis on piping and control wiring best practices. Instruction will be delivered through PowerPoint presentations, group discussions, and hands-on lab activities. In the lab, participants will be introduced to LGMV Mobile, LG’s performance evaluation tool, which is essential for assessing system operation prior to startup. Charging procedures and pre-commissioning tasks will also be addressed.
Prerequisites:
- Advanced technical knowledge of residential A/C, heat pump, and air distribution systems
- Basic proficiency in Microsoft Office programs, including Excel, PowerPoint, and Word
What to Bring:
- A laptop or PC with a web browser (Internet Explorer 8.0 or higher)
- Students who wish to have LGMV installed on their device should ensure their system meets compatibility requirements
Registration: Participants must register at https://lghvac.com/training/ to receive LG Pro Dealer credit and a certificate of completion.
Extras: Refreshments and lunch will be provided.
Class approved for 4 hours KY Masters/Journeyman, 4 hours OH, 4 hours Vanderburg Co, IN Masters, and NATE CEUs. Per state rules, repeat courses do not qualify for accumulative credits. Each class must be unique. i.e. Taking (2) Heat Pump Classes only qualifies for 4 CEUs total, whereas (1) Inverter Technology Class & (1) Heat Pump Class = 8 CEUs
Will run
Air Technologies Damper Training: Florence, KY
with Factory Representative

Certified HVAC Fire Dampers and Certified Ceiling Radiation Dampers (CRDs)
Aire Technologies HVAC fire dampers are engineered and tested to prevent the spread of fire inside the ductwork through fire-resistance-rated walls. Their fire dampers are available for both static and dynamic systems and are offered in multiple configurations to suit almost any specification. Both our standard 4¼” and thin line 2” frame profiles are constructed with interlocking curtain style blades that are offered in three types (A, B, and C) to accommodate for different air stream efficiencies.
Aire Technologies' Ceiling Radiation Dampers (CRDs) are engineered and tested to prevent heat from radiating into the truss or joist space in a floor-ceiling or roof-ceiling assembly. Their ceiling radiation dampers are offered in rectangular and round configurations as well as multiple True Truss™ enclosure types.
Lunch provided
Air Technologies Damper Training: Monroe, OH
with Factory Representative

Certified HVAC Fire Dampers and Certified Ceiling Radiation Dampers (CRDs)
Aire Technologies HVAC fire dampers are engineered and tested to prevent the spread of fire inside the ductwork through fire-resistance-rated walls. Their fire dampers are available for both static and dynamic systems and are offered in multiple configurations to suit almost any specification. Both our standard 4¼” and thin line 2” frame profiles are constructed with interlocking curtain style blades that are offered in three types (A, B, and C) to accommodate for different air stream efficiencies.
Aire Technologies' Ceiling Radiation Dampers (CRDs) are engineered and tested to prevent heat from radiating into the truss or joist space in a floor-ceiling or roof-ceiling assembly. Their ceiling radiation dampers are offered in rectangular and round configurations as well as multiple True Truss™ enclosure types.
Lunch provided